front 1 One- and two-family dwellings shall have which of the following characteristics? | back 1
|
front 2 All emergency escape and recue openings shall have a minimum net clear opening height of _________ inches. | back 2 24 |
front 3 What is the minimum required depth for the firebox of a concrete or masonry fireplace? | back 3 20 inches |
front 4 What is the minimum required clearance between combustible materials and the outside surface of a masonry heater? | back 4 36 inches |
front 5 Any factory-built chimney used for a medium-heat appliance that produces flue gases with a temperature in excess of ____°F is required to comply with UL 959. | back 5 1,000 |
front 6 What is the minimum required clearance between combustibles and all parts of a duct within 5 feet of the duct outlet? | back 6 1-inch |
front 7 The total required width of the enclosing space for a furnace or air
handler is required to be _____ inches | back 7 12 |
front 8 Table M1306.2 ______ be used to reduce the clearance required for solid-fuel appliances listed for installation with minimum clearances of 12 inches or less. | back 8 May not |
front 9 If piping is to be concealed and is installed through notches in studs of less than 1.5 inches from the nearest edge of the member, the pipe shall __________________. | back 9
|
front 10 A minimum of ______ inches in front of combustion air openings shall remain unobstructed. | back 10 6 |
front 11 Electric heat pumps shall ________________. | back 11 Listed and labeled in accordance with UL1995 |
front 12 What is the maximum allowable operating temperature for a radiant heating system operating on a gypsum assembly? | back 12 125°F |
front 13 A duct heater may only be installed within 4 feet of a heat pump or air conditioner if it is listed and labeled for such installations. | back 13 True |
front 14 Location of floor furnaces shall conform to which of the following requirements? | back 14
|
front 15 The door swing radius is prohibited to exceed _____ inches from the furnace air inlet or outlet when measured at right angles to the opening. | back 15 12 |
front 16 Room heaters shall be installed on _________. | back 16 Approved assemblies constructed of noncombustible materials that
extend at least 18 inches beyond the |
front 17 Where a cooling coil is located in the supply plenum of a warm-air
furnace, the furnace blower shall be | back 17 0.5 |
front 18 Evaporative coolers are required to be installed ______________. | back 18 on a level platform |
front 19 The air removed from bathrooms by mechanical exhaust system shall be
discharged to which of the | back 19 the outdoors |
front 20 Exhaust ducts shall be supported at intervals not to exceed _____? | back 20 12 feet |
front 21 A single-wall duct that serves a range hood shall be constructed of ______. | back 21
|
front 22 Use of a domestic open-top broiler unit requires a metal exhaust hood
with which of the following | back 22
|
front 23 Underground duct systems shall be constructed of which of the following? | back 23
|
front 24 The screens required to cover outdoor air inlets shall have openings that are a minimum of 1/4 inch and a maximum of ______ inch. | back 24 1/2 |
front 25 A solid-fuel-burning appliance will require which of the following? | back 25 combustion air |
front 26 All emergency escape and recue openings shall have a minimum net clear opening of _________ square feet. | back 26 5.7 |
front 27 Any pressure difference between the air at the regulator and the combustion air supply is to be avoided by the use of draft regulators. | back 27 True |
front 28 A flue collar for an appliance is required to be ________ than the connector. | back 28 larger |
front 29 Any vent for a natural draft appliance shall terminate a minimum of _____ feet above the highest connected appliance outlet. | back 29 5 |
front 30 A chimney connector is required to enter a masonry chimney a minimum
of ______ inches above the | back 30 6 |
front 31 What is the minimum vertical clearance required above the cook top of a freestanding or built-in range? | back 31 30 inches |
front 32 The thermostat for a sauna heater is required to limit the room temperature to a maximum of ______°F. | back 32 194°F |
front 33 The lowest piping that collects the discharge from all other drainage piping inside the house and extends 30 inches beyond the exterior walls is | back 33 building drain |
front 34 A minimum vertical developed length of _____ feet, between a horizontal branch and a drainage stack is a branch interval. | back 34 8 |
front 35 Continuous waste is defined as a drain from two or more similar adjacent fixtures connected to _______ trap. | back 35 a single |
front 36 A continuous passageway for the transmission of air is __________. | back 36 a duct system |
front 37 Air, passing through the combustion chamber and the appliance flue,
that exceeds what is theoretically | back 37 True |
front 38 A foam plastic insulation will generally have a maximum density of ______ pounds per cubic foot. | back 38 20 |
front 39 A masonry heater is a solid fuel burning heating appliance that mainly consists of concrete or solid masonry having a mass of at least 1,100 pounds, ______ the chimney and foundation. | back 39 excluding |
front 40 A shutoff valve __________ required in a system with a single low-pressure steam boiler. | back 40 is not |
front 41 Boiler discharge shall be piped, by gravity, to _____. | back 41
|
front 42 Expansion tanks are required for hot water boilers. | back 42 True |
front 43 Storage closets are ______ for the operation of fuel- fired water heaters. | back 43 prohibited |
front 44 Hydronic piping shall be hydrostatically tested using a minimum
pressure of ______ pounds per square | back 44 100 |
front 45 Piping embedded in concrete or gypsum materials, shall be _________ with a minimum rating of 100 psi at 180°F. | back 45 A. standard-weight steel pipe |
front 46 Solder joints in a metal pipe are prohibited anywhere within ________ inches of a transition from such metal pipe to PE-RT pipe. | back 46 18 |
front 47 The assembled loop system shall be pressure tested with water at _____ psi for 15 minutes with no observed leaks before connection trenches are backfilled. | back 47 100 |
front 48 What is the maximum amount of fuel oil allowed in above ground storage or inside of a building? | back 48 660 |
front 49 Where window emergency escape and rescue openings are provided, they shall have a sill height of not more than _____________ above the floor. | back 49 44 |
front 50 Fill piping will be required to terminate a minimum of ______ feet outside of a building opening at the same or lower level. | back 50 2 |
front 51 What is the maximum allowable pressure at the oil supply inlet to an appliance? | back 51 3 pounds per square inch |
front 52 Which of the following is governed by Chapter 24 of the Florida Building Code 2010, Residential. | back 52
|
front 53 53. An auxiliary drain pan ________ required for any appliance that automatically shuts down operation in the event of a stoppage in the condensate drainage system. | back 53 shall not be |
front 54 Which of the following appliances shall not be located in a sleeping room? | back 54 ![]() None of the above |
front 55 ____________ require combustion, ventilation and dilution air. | back 55
|
front 56 The source of ignition for equipment and appliances so equipped is required to be a minimum of _________ inches above the floor in hazardous locations. | back 56 18 |
front 57 Which of the following methods is required for the flashing for a vertical sidewall? | back 57
|
front 58 Gas piping will be considered to be bonded where it is connected to an appliance that is connected to the equipment grounding conductor of the circuit supplying that appliance. | back 58 True |
front 59 Exposed piping, other than steel pipe, shall be identified by a yellow label marked "Gas", in black letters, and spaced at maximum intervals of ______ feet. | back 59 5 |
front 60 What is the maximum design operating pressure for piping systems located inside buildings? | back 60 5 pounds per square inch gauge |
front 61 Anodeless risers shall be ___________. | back 61
|
front 62 Piping systems, installed underground, are required to be a minimum of ____ inches below grade. | back 62 12 |
front 63 The radius of the inner curve of plastic pipe bends for gas piping shall be a minimum of ______ times the inside diameter of the pipe. | back 63 25 |
front 64 When pressure testing piping systems, the test duration shall be a minimum of ______ minutes. | back 64 10 |
front 65 To prevent traps, piping for other than dry gas conditions shall be sloped a minimum of 0.25 inch in ____ feet. | back 65 15 |
front 66 Anytime an appliance shutoff valve is installed at a manifold, it
shall be located within ______ feet of the | back 66 50 |
front 67 A pressure regulator that requires a vent shall be vented directly _________. | back 67 to the outdoors |
front 68 What is the maximum allowable length for connectors, for gas appiances? | back 68 6 |
front 69 The connectors for a masonry chimney shall connect a minimum of ______ inches above the lowest portion of the interior of the chimney flue. | back 69 12 |
front 70 What is the minimum required thickness for an insulation shield? | back 70 26 gage |
front 71 Venting systems are prohibited from passing through which of the following? | back 71
|
front 72 The maximum common vent capacity listed in the venting tables are required to be reduced by _____ percent for each elbow up to and including 45 degrees in the common vent. | back 72 5 |
front 73 Ducts are _________ attached to wall furnaces. | back 73 prohibited from being |
front 74 The lowest portion of the floor furnace shall have a minimum of a
______-inch clearance from the grade | back 74 6 |
front 75 What is the minimum required support interval for domestic clothes dryer exhaust ducts? | back 75 4 ft |
front 76 Any warning on a sauna heater notice shall ________________. | back 76
|
front 77 For a forced-air warm-air furnace, the minimum unobstructed total area of the outside and return air ducts or openings shall be ______ square inches for each 1,000 Btu/h output rating capacity of the furnace. | back 77 2 |
front 78 What is the minimum required clearance to combustible materials at the side for a suspended-type unit heaters? | back 78 18 inches |
front 79 79. What is the maximum Btu/h per cubic foot of volume allowed for all unvented appliances installed in a room or space? | back 79 20 |
front 80 The cook top of a household cooking appliance is required to have a vertical clearance of at least 30 inches to ___________. | back 80
|
front 81 81. If an appliance pressure regulator is not supplied with an
illuminating appliance and the service line is notbequipped with a
service regulator, an appliance pressure regulator ______ installed in
the line to the | back 81 shall be |
front 82 An infrared radiant heater shall be fixed in a position separate from _______ supply lines. | back 82
|
front 83 Class _____ roofing shall be installed in areas designated by law as requiring their use or when the edge of the roof is less than 3 feet from a property line. | back 83
|
front 84 In concealed locations, where piping other than ____________, is
installed through holes or notches in | back 84 Cast-iron or galvanized steel |
front 85 Footings ______ extend below the 45-degree bearing plane of the bottom edge of a wall or footing when trenching is installed parallel to the footings. | back 85 shall not |
front 86 What is the minimum diameter for fixture tail pieces for sinks, dishwashers, laundry tubs, bathtubs and similar fixtures? | back 86 1 1/2 inches |
front 87 What is the minimum utility space required for fixtures with concealed slip-joint connections? | back 87 12 inches |
front 88 Standpipes shall extend not greater than _____ inches above the trap weir? | back 88 42 inches |
front 89 What is the minimum required interior cross sectional area for a shower compartment? (Excluding exceptions) | back 89 900 square inches |
front 90 Shower receptors are required to have a finished curb threshold a minimum of ______ inch below the sides and back of the receptor. | back 90 1 |
front 91 What is the maximum temperature a water temperature- limiting device? | back 91 120°F |
front 92 What is the minimum required diameter of sink waste outlets? | back 92 1 1/2 |
front 93 Which of the following is required for floor drains with waste outlets? | back 93
|
front 94 What is the minimum required weight for sheet copper used for flush tank linings? | back 94 10 ounces per square foot |
front 95 A pan drain shall ________________. | back 95
|
front 96 Where heated water is discharges from a solar thermal system to a hot
water distribution system, a | back 96 140 |
front 97 A temperature relief valve is required to be installed to allow the temperature-sensing element to monitor the water within the top ____ inches of the tank. | back 97 6 |
front 98 Flush tanks are required to be equipped with an anti-siphon fill
valve backflow preventer installed a | back 98 1 |
front 99 What is the maximum static pressure for a water supply system? | back 99 80 psi |
front 100 Protection from exposure in the form of ____________ is required for nonmetallic pipe and tubing systems. | back 100
|
front 101 Solders and fluxes used for joints in potable water- supply systems shall be required to have a maximum of ___ percent lead. | back 101 0.2 |
front 102 Buildings and structures, including all related parts, are required to be constructed to safely support which of the following? | back 102
|
front 103 If a roof surface adjacent to a wall or walls is at the same elevation, the parapet shall extend a minimum of ______ inches above the roof surfaces. | back 103 30 |
front 104 Mechanical and gravity outdoor air intake openings shall be located at least ______ feet from any hazardous or noxious contaminant. such as vents, chimneys, plumbing vents, streets, alleys, parking lots and loading docks, except as otherwise specified in this code. | back 104 10 |
front 105 What shall not be considered as contributing to the minimum required habitable area for a room? | back 105
|
front 106 A basement that does not include habitable space, hallways, bathrooms, toilet rooms and laundry rooms is required to have a minimum ceiling height of ______. | back 106 6 feet 8 inches |
front 107 Sloped glazing is defined as glass or other transparent or translucent glazing material installed at a minimum slope of ______ degrees from vertical. | back 107 15 |
front 108 Emergency and escape rescue openings shall have a net clear opening of not less than ______ square feet. | back 108 5.7 |
front 109 What is the minimum required headroom, in all parts of a stairway, measured vertically from the sloped line adjoining the tread nosing or from the floor surface of the landing or platform on that portion of the stairway? on that portion of the stairway. | back 109 6 feet 8 inches |
front 110 Required guards shall be located along open-sided walking surfaces, including stairs, ramps and landings, if they are located more than ______ inches measured vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. | back 110 30 |
front 111 Foam plastics __________ permitted as interior finish. | back 111 shall be |
front 112 The quality mark, required on each piece of pressure- preservative-treated lumber or plywood, shall include ____________. | back 112 identification of treating plant |
front 113 An area that is considered to be subject to wave heights in excess of
______ feet or subject to high- | back 113 3 |
front 114 Water service pipe shall be installed _______. | back 114
|
front 115 What is the minimum required weight for sheet copper for general use? | back 115 12 ounces per square feet |
front 116 Joints for hub and spigot pipe are required to be ________. | back 116
|
front 117 Cleanouts shall be installed a maximum of ______ feet apart in horizontal drainage lines when measured from the upstream entrance of the cleanout. | back 117 100 |
front 118 _______ that receive the discharge of water closets shall be capable
of handling spherical solids with a | back 118
|
front 119 Plumbing systems, with a system of vent piping permitting the admission or emission of air that allows the seal of any fixture trap is required to be subjected to a pneumatic pressure differential of more than _____ inch(es) of water column. | back 119 1 |
front 120 Open vent pipes that extend through a roof shall be terminated a
minimum of __________, whichever is | back 120
|
front 121 Every dry vent shall rise vertically to at least _____ inches above the flood level rim of the highest trap or trapped fixture being vented. | back 121 6 |
front 122 A vent will be required to be installed at least ______ pipe diameters away from the trap weir. | back 122 two |
front 123 A single horizontal wet vent may be used to vent any combination of fixtures within two bathroom groups and located on the same floor level. | back 123 True |
front 124 A waste stack ______ used as a vent for all of the fixtures discharging to the stack. | back 124 may be |
front 125 What is the maximum allowable slope of the vent section of a horizontal branch drain? | back 125 8-percent slope |
front 126 If the size of the trap is 1 1⁄4 inches and the slope is 1⁄4 inches per foot, the maximum distance of the fixture trap from the vent must be ____________ feet. | back 126 5 |
front 127 A vent or branch vent for multiple island fixture vent should extend at least ______ inches above the highest island fixture being vented. | back 127 6 |
front 128 What is the maximum diameter for a vent pipe? | back 128 1 1/4 |
front 129 If an air admittance valve is installed in an attic, it shall be installed at least ______ inches above insulation materials. | back 129 6 |
front 130 Traps will be required to have a liquid seal of __________. | back 130
|
front 131 A subsoil drain shall be a minimum of ______ inches in diameter. | back 131 4 |
front 132 A sump pit shall be a minimum of 18 inches in diameter and ______
inches deep, unless otherwise | back 132 24 |
front 133 Lots shall be graded, to fall a minimum of 6 inches within the first
______ feet, to drain surface water | back 133 10 |
front 134 A fastener that is used below grade to attach plywood to the exterior side of exterior basement wall studs shall be of Type ______ stainless steel. | back 134
|
front 135 What is the minimum required thickness for spread footings? | back 135 8 inches |
front 136 Concrete and masonry foundation walls will be required to extend a minimum of __ inches above the finished grade adjacent to the foundation for a masonry veneer. | back 136 4 |
front 137 What is the minimum thickness of portland cement parging required to
be applied to the exterior of a | back 137 3/8 inch |
front 138 What is the minimum required nominal size for structural wood columns? | back 138 4 x 4 |
front 139 Mechanical exhaust ventilation operating continuously at a rate equal to ______ cubic foot per minute for each 50 square feet of crawlspace floor area, including an air pathway to the common area, and perimeter walls, shall not require ventilation openings. | back 139 1 |
front 140 Hair and lint strainers are required in the pool circulating pumps when used with a pressure filter. | back 140 True |
front 141 Structural glue-laminated members are prohibited, without exception. | back 141 False |
front 142 ______ shall be pressure preservative treated and dried after treatment. | back 142
|
front 143 Concrete slab-on-ground floors shall be at least ______ inches thick. | back 143 3.5 |
front 144 Which of the following shall not extend beneath walls, partitions or columns which are fastened to the floor? | back 144
|
front 145 Mortar joint thickness for a load-bearing masonry wall shall be the same for which of the following? | back 145 head joints and collar joints |
front 146 When bonding with wall ties, there shall be at least one metal tie for each ______ square feet of wall area. | back 146 4.5 |
front 147 The maximum spacing of reinforcement shall be inches provided that
the walls are solid | back 147 48 |
front 148 If design wind pressure is ______ psf, the maximum area of each individual standard-unit glass panel shall be 144 square feet. | back 148 20 |
front 149 A construction joints, in a plain concrete wall, including a wall that is required to have a minimum of No.4 bars at _____ inches on center, shall be located at points of lateral support. | back 149 48 |
front 150 The bottom surface of footings shall not have a slope exceeding one unit vertical in units horizontal. | back 150 10 |
front 151 What is the maximum side dimension, centered in the panel core, for
the maximum vertical chase | back 151 2 inches |
front 152 Exterior sheathing shall be _______ before applying an exterior cover. | back 152 dry |
front 153 The finish coat for two-coat cement plaster shall not be applied sooner than ______ hours after application of the first coat. | back 153 48 |
front 154 What is the maximum nominal air space allowed between a masonry veneer and the sheathing? | back 154 4 1/2 |
front 155 Anytime expansive or collapsible soils are known to exist, dwellings
are required to have a means of | back 155 5 |
front 156 Wood structural panel used as roof sheathing shall be installed with joints ____________. | back 156 staggard |
front 157 Insulation shall not block the free flow of air when eave or cornice vents are installed and a minimum of a ______-inch space is required between the insulation and the roof sheathing and at the location of the vent. | back 157 1 |
front 158 If a building is constructed with a combustible ceiling or roof, what is the required maximum attic access opening to attic areas? | back 158 30 square feet |